The recorded checkValve.dp channel spans -200,000 to 200,000 Pa in this reference run. It starts at -200,000 and ends at 200,000. The first recorded maximum occurs at 1 seconds and the first minimum at 0 seconds.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named CheckValve. The source file places it under Fluid, Fixed Resistances. We used the 101 stored values for checkValve.dp over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name P_dp (Ramp), sou (Boundary p T), sin (Boundary p T), checkValve (Check Valve). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel checkValve_m_flow.dp covers 0 to 22,500 Pa. At 0 s, the primary value is -200,000 and the companion is 0. Their signed difference is -200,000 Pa, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Fixed resistances check valve. The simulated checkValve.dp channel runs from -200,000 to 200,000 Pa over 1 seconds.
Fixed resistances check valve. The simulated checkValve.dp channel runs from -200,000 to 200,000 Pa over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.49 to 0.5 seconds. Subtracting -4,000 from 1.16e-10 gives 4,000 Pa. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

checkValve.dp (Pa)

checkValve_m_flow.dp (Pa)

0

-200000

0

0.2

-120000

1267.598

0.4

-40000

3600

0.49

-4000.004

5402.25

0.5

1.164153e-10

5625

0.6

39999.99

8099.999

0.8

120000

14400

1

200000

22500

What to check on site

Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

Cover photograph by Daniel Dan, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.