The soi.port_a.T trace covers -10.294 to 33.435 °C, a temperature span of 43.728 K. The first recorded maximum occurs at 48,384 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named FiniteDifference_1Week. The source file places it under Fluid, Geothermal, Borefields, Heat Transfer. We used the 101 stored values for soi.port_a.T over the interval 0 to 604,800 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name soi (Cylindrical), preHeaFlo (Prescribed Heat Flow), sine (Sine), groTemRes (Ground Temperature Response). The source declares T_start = 283.15. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel deltaT.y starts at 0, ends at -0.3008 and has a recorded range of -0.3182 to 0.2967 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 66,528 to 72,576 seconds. Subtracting 291.956 from 282.833 gives -9.123 K. Its location brackets the change within one saved interval of 6,048 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | soi.port_a.T (K) | deltaT.y (source units) |
|---|---|---|
0 | 283.15 | 0 |
48384 | 306.5846 | 0.2682766 |
66528 | 291.9562 | -0.03161417 |
72576 | 282.8331 | -0.1443277 |
120960 | 293.6776 | 0.1917236 |
241920 | 286.6805 | -0.1261076 |
362880 | 269.0099 | -0.1431929 |
483840 | 303.7163 | 0.1821055 |
526176 | 262.8563 | -0.263381 |
604800 | 264.8873 | -0.3007688 |
What to check on site
The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model