The recorded fan1.dp channel spans -27,388 to 0 Pa in this reference run. It starts at 0 and ends at -4.11e-06. The first recorded maximum occurs at 0 seconds and the first minimum at 48 seconds.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named ControlledFlowMachine. The source file places it under Fluid, Movers. We used the 101 stored values for fan1.dp over the interval 0 to 600 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 8 recorded variables. Alongside the primary output there are fan1.m_flow, fan2.m_flow, fan3.m_flow, fan4.m_flow, fan1.dp. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel fan2.dp covers -27,388 to 0 Pa. At 72 s, the primary value is -1,275 and the companion is -840.394. Their signed difference is -434.557 Pa, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Fans with different control signals as input. The simulated fan1.dp channel runs from -27,388 to 0 Pa over 600 seconds.
Fans with different control signals as input. The simulated fan1.dp channel runs from -27,388 to 0 Pa over 600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 180 to 186 seconds. Subtracting -27,388 from -7,984 gives 19,404 Pa. Its location brackets the change within one saved interval of 6 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

fan1.dp (Pa)

fan2.dp (Pa)

0

0

0

48

-27388.48

-27388.48

120

-1.44825e-06

-1.1714e-06

180

-27387.71

-27387.71

186

-7984.093

-7984.093

240

-4.110319e-06

-5.142836e-06

360

-4.110363e-06

-5.142851e-06

480

-4.110319e-06

-5.142851e-06

600

-4.110319e-06

-5.142821e-06

What to check on site

Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.