The fan1.dp trace ranges from -27,388.2 Pa to 0 Pa across 101 saved checkpoints. It begins at 0 Pa and finishes at -5.196e-07 Pa after 600 s of test time. The source identifies the channel scale as Pa. Its first saved maximum occurs at 0 s.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named ControlledFlowMachineDynamic. The source file places it under Fluid, Movers. We used the 101 stored values for fan1.dp over the interval 0 to 600 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 8 recorded variables. Alongside the primary output there are fan1.m_flow, fan2.m_flow, fan3.m_flow, fan4.m_flow, fan1.dp. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

At 6 s, fan1.dp is -17,029.6 Pa and fan2.dp is -1,237.2 Pa. Subtracting the second value from the first gives -15,792.5 Pa. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Fans with different control signals as input and a dynamic speed signal. The simulated fan1.dp channel runs from -27,388 to 0 Pa over 600 seconds.
Fans with different control signals as input and a dynamic speed signal. The simulated fan1.dp channel runs from -27,388 to 0 Pa over 600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 60 to 66 seconds. Subtracting -27,388 from -7,985 gives 19,403 Pa. Its location brackets the change within one saved interval of 6 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

fan1.dp (Pa)

fan2.dp (Pa)

0

0

0

60

-27388.22

-27386.88

66

-7985.091

-23556.56

120

-5.200855e-07

-0.1542248

240

-5.195761e-07

-0.1541806

360

-5.195761e-07

-0.1541807

480

-5.195761e-07

-0.1541807

600

-5.195761e-07

-0.1541806

What to check on site

Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.