The floMacDyn.dpMachine trace ranges from 4.616e-08 Pa to 500.037 Pa across 101 saved checkpoints. It begins at 250 Pa and finishes at 4.616e-08 Pa after 1 s of test time. The source identifies the channel scale as Pa. Its first saved maximum occurs at 0.07 s.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named FlowControlled_m_flow. The source file places it under Fluid, Movers. We used the 101 stored values for floMacDyn.dpMachine over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 5 recorded variables. Alongside the primary output there are gain.u, floMacSta.dpMachine, floMacDyn.dpMachine, floMacSta.VMachine_flow, floMacDyn.VMachine_flow. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
At 0 s, floMacDyn.dpMachine is 250 Pa and floMacSta.dpMachine is 500 Pa. Subtracting the second value from the first gives -250 Pa. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 0.01 seconds. Subtracting 250 from 475.692 gives 225.692 Pa. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | floMacDyn.dpMachine (Pa) | floMacSta.dpMachine (Pa) |
|---|---|---|
0 | 250 | 500 |
0.01 | 475.6917 | 500 |
0.07 | 500.0365 | 500 |
0.2 | 500.0051 | 500 |
0.4 | 247.4784 | 245 |
0.6 | 45.41555 | 45.00001 |
0.8 | 1.101333e-06 | 0 |
1 | 4.615868e-08 | 0 |
What to check on site
Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.