The zon.TAir trace covers 10.458 to 20 °C, a temperature span of 9.542 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named NoOutputVariable. The source file places it under Thermal Zones, Energy Plus 24 2 0, Output Variable. We used the 101 stored values for zon.TAir over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 1 recorded variables. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The primary channel spends 17.8% of its saved checkpoints at or above 288.379 K, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 286.504 K. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 864 seconds. Subtracting 293.15 from 290.598 gives -2.552 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | zon.TAir (K) |
|---|---|
0 | 293.15 |
864 | 290.5975 |
17280 | 285.6974 |
34560 | 286.9446 |
51840 | 288.2599 |
69120 | 285.3321 |
86400 | 283.6084 |
What to check on site
Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.