The lowest observed group mean is 10.947 for liner outside diameter group 2. The highest is 13.236 for group 1, a difference of 2.289 on the source response scale. Across all 16 numeric records the response median is 13.47.

What was measured

The QUINLAN2 data file has 50 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as % shrinkage. It preserves the source scale and its sign. The file contains 16 numeric fields per accepted row.

Spread across the original readings

The two endpoint groups have 8 and 8 observations. Their medians are 10.22 and 14.54, respectively. The figure groups the original entries by the recorded liner outside diameter value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

Extrusion liner shrinkage. The lowest and highest group means are 10.947 and 13.236 on the source response scale.
Extrusion liner shrinkage. The lowest and highest group means are 10.947 and 13.236 on the source response scale. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 5 after the header. Its response is 14.03. The overall arithmetic mean is 12.092, so this observation is 1.938 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 8.945, calculated by subtracting 6.68 from 15.625.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

liner outside diameter group

Observations

Mean response

Median response

Minimum response

Maximum response

1

8

13.23625

14.54

4.8

21.04

2

8

10.9475

10.22

4.68

17.67

Implications for an industrial comparison

A production acceptance sample should identify the item, instrument, operator and measurement method before the result is pooled. Document fixture setup and any intermediate processing. Repeatability from one instrument and reproducibility across operators or locations require different comparison groups.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.