The solEn.vol[1].T trace covers 0.1456 to 98.736 °C, a temperature span of 98.59 K. The first recorded maximum occurs at 82,944 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ExtremeAmbientConditions. The source file places it under Fluid, Solar Collectors. We used the 101 stored values for solEn.vol[1].T over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name solAsh (ASHRAE93), solEn (EN12975), sou (Mass Flow Source T), sou1 (Boundary p T). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel solAsh.vol[1].T covers 273.19 to 371.935 K. At 67,392 s, the primary value is 317.025 and the companion is 370.219. Their signed difference is -53.195 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Extreme ambient conditions. The simulated solEn.vol[1].T channel runs from 273.296 to 371.886 K over 86,400 seconds.
Extreme ambient conditions. The simulated solEn.vol[1].T channel runs from 273.296 to 371.886 K over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 78,624 to 79,488 seconds. Subtracting 360.854 from 364.452 gives 3.598 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

solEn.vol[1].T (K)

solAsh.vol[1].T (K)

0

313.15

313.15

17280

295.011

273.5993

34560

273.3072

273.192

35424

273.2956

273.1902

51840

277.3296

289.6588

69120

323.2636

371.6586

78624

360.8537

371.9241

79488

364.4521

371.9345

82944

371.8856

371.9345

86400

371.8856

371.9345

What to check on site

Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

Cover photograph by Connor Scott McManus, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.