The recorded senPPM.ppm channel spans 0 to 866.923 source units in this reference run. It starts at 0 and ends at 866.923. The first recorded maximum occurs at 7,200 seconds and the first minimum at 0 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named TraceSubstances. The source file places it under Fluid, Sensors. We used the 101 stored values for senPPM.ppm over the interval 0 to 7,200 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name vol (Mixing Volume), sou (Trace Substances Flow Source), step (Constant), senVol (Trace Substances). The source declares m_flow_nominal = 15*1.2/3600. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel senTraSub.C covers 0 to 0.001325 source units. At 7,200 s, the primary value is 866.923 and the companion is 0.001325. Their signed difference is 866.922 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 72 seconds. Subtracting 0 from 17.688 gives 17.688 source units. Its location brackets the change within one saved interval of 72 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | senPPM.ppm (source units) | senTraSub.C (source units) |
|---|---|---|
0 | 0 | 0 |
72 | 17.68793 | 2.703832e-05 |
1440 | 303.4299 | 0.0004638325 |
2880 | 520.4545 | 0.0007955833 |
4320 | 675.8271 | 0.001033091 |
5760 | 787.156 | 0.001203272 |
7200 | 866.923 | 0.001325206 |
What to check on site
Record the physical quantity and its reference state before checking agreement. A sensor model can include a delay or mixing volume that an algebraic reference omits. Align both acquisition time and location before interpreting a difference as calibration error.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.