The conExt[1].win.glaUns.glass_a.T trace covers -14.772 to 7.68 °C, a temperature span of 22.453 K. The first recorded maximum occurs at 133,056 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named ExteriorWallTwoWindows. The source file places it under Thermal Zones, Detailed, Constructions. We used the 101 stored values for conExt[1].win.glaUns.glass_a.T over the interval 0 to 1,209,600 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name bouConExt (Exterior Boundary Conditions With Window), TRoo (Fixed Temperature), theCol (Thermal Collector), uSha (Constant). The source declares nCon = 2. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel conExt[1].opa.T[1] covers 250.374 to 303.19 K. At 387,072 s, the primary value is 267.331 and the companion is 296.501. Their signed difference is -29.17 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.
![Exterior wall with two windows, one having a shade, the other not. The simulated conExt[1].win.glaUns.glass_a.T channel runs from 258.378 to 280.83 K over 1,209,600 seconds.](https://static.wixstatic.com/media/21e41b_0a1eb8339e40450b991df279135a5326~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_0a1eb8339e40450b991df279135a5326~mv2.png)
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 36,288 to 48,384 seconds. Subtracting 269.33 from 274.287 gives 4.956 K. Its location brackets the change within one saved interval of 12,096 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | conExt[1].win.glaUns.glass_a.T (K) | conExt[1].opa.T[1] (K) |
|---|---|---|
0 | 266.8629 | 293.15 |
36288 | 269.3304 | 289.7743 |
48384 | 274.2868 | 277.2946 |
133056 | 280.8304 | 278.6801 |
241920 | 274.6341 | 269.7516 |
483840 | 266.921 | 268.2775 |
532224 | 258.3776 | 251.3596 |
725760 | 270.7525 | 279.6602 |
967680 | 277.6977 | 274.7038 |
1209600 | 265.3043 | 257.4308 |
What to check on site
Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.


![Exterior wall with two windows, one having a shade, the other not. conExt[1].win.glaUns.glass_a.T (K) ranges from 258.38 to 280.83 across the recorded simulation time (s) interval of 0 to 1.2096e+06. Bands show the minimum and maximum per group of samples. Crossbars mark the median.](/story-art/fa31bc75d33601998.webp)