The eas.hF trace ranges from 5.4535 to 10.907 across 101 saved checkpoints. It begins at 10.907 and finishes at 10.907 after 3,600 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Exterior. The source file places it under Heat Transfer, Convection. We used the 101 stored values for eas.hF over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name nor (Exterior), wes (Exterior), sou (Exterior), eas (Exterior). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 3,528 s, eas.hF reads 10.907 and nor.hF reads 10.907. Across the run, the second channel ranges from 5.4535 to 10.907. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 3,492 to 3,528 seconds. Subtracting 7.006 from 10.907 gives 3.901 source units. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

eas.hF (source units)

nor.hF (source units)

0

10.90709

10.90709

720

10.90709

10.90709

1440

10.90709

5.453547

1944

5.453547

5.453547

2160

5.453547

5.453547

2880

5.453547

10.90709

3492

7.006341

10.90709

3528

10.90709

10.90709

3600

10.90709

10.90709

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.