The recorded extConvForcedCoeffFloor.winDir channel spans -6.283 to 6.283 source units in this reference run. It starts at -6.283 and ends at 6.283. The first recorded maximum occurs at 1 seconds and the first minimum at 0 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named ExtConvForcedCoeff. The source file places it under Buildings, Components, Convective Heat Transfer. We used the 101 stored values for extConvForcedCoeffFloor.winDir over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name extConvForcedCoeffWall (Ext Conv Forced Coeff), winDir (Ramp), winSpe (Constant), extConvForcedCoeffCeiling (Ext Conv Forced Coeff). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel extConvForcedCoeffWall.hForcedConExt covers 9.583 to 13.655 source units. At 0 s, the primary value is -6.283 and the companion is 13.655. Their signed difference is -19.938 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Ext conv forced coeff. The simulated extConvForcedCoeffFloor.winDir channel runs from -6.283 to 6.283 source units over 1 seconds.
Ext conv forced coeff. The simulated extConvForcedCoeffFloor.winDir channel runs from -6.283 to 6.283 source units over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.18 to 0.19 seconds. Subtracting -4.021 from -3.896 gives 0.1257 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

extConvForcedCoeffFloor.winDir (source units)

extConvForcedCoeffWall.hForcedConExt (source units)

0

-6.283185

13.65529

0.18

-4.021239

13.65529

0.19

-3.895575

13.65529

0.2

-3.769911

13.65529

0.4

-1.256637

9.582809

0.6

1.256637

13.65529

0.8

3.769911

9.582809

1

6.283185

13.65529

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.