The err trace ranges from 0 to 8.045e-06 across 101 saved checkpoints. It begins at 0 and finishes at 3.401e-06 after 15 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named FiniteLineSource_Erfint. The source file places it under Fluid, Geothermal, Borefields, Heat Transfer, Thermal Response Factors. We used the 101 stored values for err over the interval 0 to 15 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name u (Real), erfint (Real), erfint_num (Real), err (Real). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The two named channels have separate paths in the model. err begins at 0 and ends at 3.4009e−06. erfint begins at 0 and ends at 14.436. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.15 to 0.3 seconds. Subtracting 3.4e-06 from 7.01e-06 gives 3.61e-06 source units. Its location brackets the change within one saved interval of 0.15 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

err (source units)

erfint (source units)

0

0

0

0.15

3.40374e-06

0.01264687

0.3

7.010166e-06

0.05002889

1.8

8.044653e-06

1.238269

3

3.360695e-06

2.435814

6

3.400882e-06

5.435811

9

3.400882e-06

8.43581

12

3.400882e-06

11.43581

15

3.400882e-06

14.43581

What to check on site

The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Checking the two recorded channels

At 0.3 s, err reads 7.01e-06 and erfint reads 0.050029. Across the run, the second channel ranges from 0 to 14.436. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.