The recorded eff1.WHyd channel spans 4,404 to 13,217 source units in this reference run. It starts at 4,404 and ends at 13,217. The first recorded maximum occurs at 1 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named EulerReducedSpeed. The source file places it under Fluid, Movers. We used the 101 stored values for eff1.WHyd over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name eff1 (Flow Machine Interface), eff2 (Flow Machine Interface), eff3 (Flow Machine Interface), y1 (Constant). The source declares rhoCon = 1.2. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel pow1 covers 4,827 to 11,878 source units. At 1 s, the primary value is 13,217 and the companion is 11,303. Their signed difference is 1,914 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Euler number method at reduced mover speed. The simulated eff1.WHyd channel runs from 4,404 to 13,217 source units over 1 seconds.
Euler number method at reduced mover speed. The simulated eff1.WHyd channel runs from 4,404 to 13,217 source units over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.12 to 0.13 seconds. Subtracting 6,329 from 6,491 gives 162.675 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

eff1.WHyd (source units)

pow1 (source units)

0

4403.793

4827.096

0.12

6328.686

6434.018

0.13

6491.36

6567.928

0.2

7599.72

7516.779

0.4

10035.74

10006.55

0.6

11166.82

11300.15

0.8

12639.23

11832.33

1

13217.48

11303.35

What to check on site

Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model