The recorded eff1.dp channel spans 0 to 3,016 Pa in this reference run. It starts at 3,016 and ends at 0. The first recorded maximum occurs at 0 seconds and the first minimum at 1 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named EulerComparison. The source file places it under Fluid, Movers. We used the 101 stored values for eff1.dp over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name eff1 (Flow Machine Interface), eff2 (Flow Machine Interface), y (Constant), rho (Constant). The source declares rhoCon = 1.2. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel P1 starts at 4,690, ends at 11,253 and has a recorded range of 4,690 to 11,878 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Euler number method at nominal mover speed. The simulated eff1.dp channel runs from 0 to 3,016 Pa over 1 seconds.
Euler number method at nominal mover speed. The simulated eff1.dp channel runs from 0 to 3,016 Pa over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.95 to 0.96 seconds. Subtracting 344.096 from 274.757 gives -69.339 Pa. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

eff1.dp (Pa)

P1 (source units)

0

3015.762

4690.453

0.2

3010.433

7430.998

0.4

2966.32

9987.779

0.6

2323.702

11307.74

0.8

1278.496

11842.16

0.95

344.0958

11532.16

0.96

274.7568

11473.53

1

0

11252.61

What to check on site

Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

Cover photograph by Mikhail Nilov, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.