The recorded absChi.QCon_flow channel spans 0 to 22,762 W in this reference run. It starts at 0 and ends at 18,138. The first recorded maximum occurs at 25,458 seconds and the first minimum at 23,500 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named AbsorptionIndirectSteam_EnergyPlus. The source file places it under Fluid, Chillers. We used the 101 stored values for absChi.QCon_flow over the interval 23,500 to 32,400 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name absChi (Absorption Indirect Steam), conPum (Mass Flow Source T), evaPum (Mass Flow Source T), cooVol (Boundary p T). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel QCon_EP.y starts at 0, ends at 18,270 and has a recorded range of 0 to 22,900 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Reproduce the calculation
Integrating the signed absChi.QCon_flow samples by the trapezoidal rule gives 32.816 kWh over 8,900 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | absChi.QCon_flow (W) | QCon_EP.y (source units) |
|---|---|---|
23500 | 0 | 0 |
25191 | 0 | 0 |
25280 | 22141.79 | 22210 |
25458 | 22762.03 | 22900 |
27060 | 18356.03 | 18680 |
28840 | 18226.15 | 18510 |
30620 | 17904.66 | 18080 |
32400 | 18138.4 | 18270 |
What to check on site
Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.