The recorded opeModWarUpEngTem.QGen_flow channel spans 26,142 to 134,444 W in this reference run. It starts at 134,444 and ends at 26,142. The first recorded maximum occurs at 0 seconds and the first minimum at 960 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named EnergyConversionWarmUp. The source file places it under Fluid, CH Ps. We used the 101 stored values for opeModWarUpEngTem.QGen_flow over the interval 0 to 1,500 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name opeModWarUpEngTem (Energy Conversion Warm Up), TEng (Ramp), mWat_flow (Constant), TWatIn (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel opeModWarUpEngTem.TEng starts at 288.15, ends at 378.15 and has a recorded range of 288.15 to 378.15 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Reproduce the calculation
Integrating the signed opeModWarUpEngTem.QGen_flow samples by the trapezoidal rule gives 31.797 kWh over 1,500 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | opeModWarUpEngTem.QGen_flow (W) | opeModWarUpEngTem.TEng (source units) |
|---|---|---|
0 | 134444.4 | 288.15 |
300 | 134444.4 | 288.15 |
600 | 134444.4 | 288.15 |
645 | 115024.7 | 299.4 |
660 | 89629.63 | 303.15 |
900 | 28681.48 | 363.15 |
960 | 26141.97 | 378.15 |
1200 | 26141.97 | 378.15 |
1500 | 26141.97 | 378.15 |
What to check on site
Compare fuel or electrical input with useful heat at a declared delivery boundary. Include the warm-up interval and any period on standby. Separate a temperature setpoint from the measured outlet and keep auxiliary energy in a stated part of the balance.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.
Cover photograph by Jakub Zerdzicki, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.