The published limPID.y signal spans -1 to 0.744 source signal units in the reference run. It starts at 0.5 and finishes at -1. The signed change between those endpoint samples is -1.5 source signal units.

What the reference test measures

The Buildings model named PIDWithEnable comes from Lawrence Berkeley National Laboratory. The saved result covers simulation time 0 to 1 seconds. Industry Applied extracted 101 checkpoints for limPID.y and kept the original signed values. The regular output spacing is 0.01 seconds. The solver may take different internal steps.

The model definition identifies limPID (PID With Enable), noLimPID (PID With Enable), pulse (Pulse). These component names let a reader trace the plotted tags to their owning blocks before reproducing the result.

Settings to preserve when repeating the experiment

The published test declares pulse.period = 0.25, limPID.Ti = 1, limPID.Td = 1. Those numbers use the units and component definitions in the linked model. Start with the declared configuration when reproducing the reference result, then vary one setting at a time. Changing the input waveform and the component response in the same comparison makes it difficult to identify the source of a difference.

Reading the two channels

At 0.15 seconds, limPID.y is 0.744 and noLimPID.y is -1e+15. Subtracting the second channel from the first gives +1e+15 source signal units, the largest absolute separation on their common saved grid. The channels have distinct roles in the model, so this difference describes the two traces and is not a calibrated instrument error.

Enabled regulator command. In the simulated PIDWithEnable case, limPID.y ranges from -1 to 0.744 source signal units over 1 seconds.
Enabled regulator command. In the simulated PIDWithEnable case, limPID.y ranges from -1 to 0.744 source signal units over 1 seconds. Figure by Industry Applied.

Reproducing the largest recorded change

Between the stored points at 0.15 and 0.16 seconds, limPID.y changes from 0.744 to -1. Subtracting the earlier reading gives -1.744 source signal units. This interval contains the largest absolute point-to-point change in the saved primary channel. A faster excursion followed by recovery could fit entirely between the two records.

The extrema in the table and figure are extrema of the stored series. A solver’s internal peak, a field logger’s alarm value and a maximum derived from this export can differ. Preserve the sampling settings when comparing results.

Worked data

Simulation time (s)

limPID.y (signal units)

noLimPID.y (signal units)

0

0.5

0.5

0.04

-1

-1e+15

0.15

0.7438065

-1e+15

0.16

-1

-1e+15

0.25

-1

-1e+15

0.5

-1

-1e+15

0.75

-1

-1e+15

1

-1

-1e+15

Applying the result to an operating site

An enable signal, a reset and a command limit are different operations. Capture the state at the instant enable changes, including the feedback and setpoint. A smooth return depends on the stored internal state and configured limits.

For an Australian monitoring project, write the intended sample interval, timestamp convention, tag units and missed-update policy into the acceptance record. Re-run this comparison on the installed signal path and retain the raw export so a later dashboard change can be checked against the same baseline.