The recorded zone.TSensor channel spans 291.801 to 293.15 source units in this reference run. It starts at 293.15 and ends at 292.116. The first recorded maximum occurs at 0 seconds and the first minimum at 29,000 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named EmbeddedPipeNDiscr. The source file places it under Fluid, Heat Exchangers, Radiant Slab. We used the 101 stored values for zone.TSensor over the interval 0 to 100,000 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 6 recorded variables. Alongside the primary output there are QFlows[1], QFlows[2], QFlows[3], zone.TSensor, zone1.TSensor. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel zone1.TSensor covers 291.776 to 293.15 source units. At 100,000 s, the primary value is 292.116 and the companion is 292.065. Their signed difference is 0.05054 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Embedded pipe n discr. The simulated zone.TSensor channel runs from 291.801 to 293.15 source units over 100,000 seconds.
Embedded pipe n discr. The simulated zone.TSensor channel runs from 291.801 to 293.15 source units over 100,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 1,000 seconds. Subtracting 293.15 from 292.47 gives -0.6801 source units. Its location brackets the change within one saved interval of 1,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

zone.TSensor (source units)

zone1.TSensor (source units)

0

293.15

293.15

1000

292.4699

292.4698

20000

291.9678

291.947

29000

291.8007

291.7758

40000

292.2362

292.2028

60000

292.3662

292.3239

80000

292.1636

292.1172

100000

292.116

292.0655

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.