The lowest observed group mean is 1.082 for coded acceptor density (in cm**-3 group 200 to 1,000. The highest is 4.543 for group 1 to 10, a difference of 3.461 on the source response scale. Across all 21 numeric records the response median is 2.489.

What was measured

The BENNETT data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as electron mobility for p-type AlGaAs. It preserves the source scale and its sign. The file contains 8 numeric fields per accepted row.

Spread across the original readings

The two endpoint groups have 5 and 6 observations. Their medians are 1.068 and 4.471, respectively. The figure groups the original entries by the recorded coded acceptor density (in cm**-3 value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

Electron mobility in aluminium gallium arsenide. The lowest and highest group means are 1.082 and 4.543 on the source response scale.
Electron mobility in aluminium gallium arsenide. The lowest and highest group means are 1.082 and 4.543 on the source response scale. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 19 after the header. Its response is 2.489. The overall arithmetic mean is 2.631, so this observation is -0.1417 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 2.026, calculated by subtracting 1.539 from 3.565.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

coded acceptor density (in cm**-3 group

Observations

Mean response

Median response

Minimum response

Maximum response

1 to 10

6

4.543167

4.4715

3.565

5.742

20 to 100

5

2.2344

2.145

1.643

2.926

200 to 1,000

5

1.08214

1.068

0.9901

1.258

2,000 to 10,000

5

2.2808

2.489

1.539

2.72

Implications for an industrial comparison

Record fixture connections, instrument range, excitation level and temperature alongside the measured result. Repeatability within one setup can remain good even when fixtures differ between laboratories. A useful acceptance run includes both a repeat measurement without disturbing the setup and a repeat after a normal reconnection.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.