The archived response ranges from 2.997 to 11.038. The median is 6.923 and the central half of the measurements extends from 6.052 to 7.941. Those figures use all 59 numeric observations in this source series and retain its original measurement scale.

What was measured

The NELSNIST data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as hours to failure. It preserves the source scale and its sign. The file contains 1 numeric field per accepted row.

Spread across the original readings

The tenth percentile is 4.948 and the ninetieth is 9.225. They provide a narrower description of the typical spread than the minimum and maximum. The largest and smallest observed records are separated by 8.041. This is the range of this sample, rather than a guaranteed operating envelope.

Electromigration time to failure. The 25th, 50th and 75th percentiles of the measurements are 6.052, 6.923 and 7.941.
Electromigration time to failure. The 25th, 50th and 75th percentiles of the measurements are 6.052, 6.923 and 7.941. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 29 after the header. Its response is 6.923. The overall arithmetic mean is 6.98, so this observation is -0.05707 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 1.889, calculated by subtracting 6.052 from 7.941.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

Percentile

Observed response (source scale)

Number of numeric rows

0

2.997

59

10

4.9484

59

25

6.052

59

50

6.923

59

75

7.941

59

90

9.2252

59

100

11.038

59

Implications for an industrial comparison

Compare the specimen geometry, preparation, loading direction, conditioning and endpoint before using this distribution in a materials decision. Failure observations from a controlled test do not directly provide a field failure probability. A comparison with current production also needs the number of specimens withdrawn before the stated endpoint.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.

Cover photograph by Mikhail Nilov, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.