The conWin.T trace covers 20 to 25 °C, a temperature span of 5 K. The first recorded maximum occurs at 22,464 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ElectrochromicWindow. The source file places it under Thermal Zones, Detailed, Controls. We used the 101 stored values for conWin.T over the interval 0 to 172,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name TMea (Trapezoid), HMea (Trapezoid). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel conWin.y starts at 0, ends at 0 and has a recorded range of 0 to 1 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Electrochromic window. The simulated conWin.T channel runs from 293.15 to 298.15 K over 172,800 seconds.
Electrochromic window. The simulated conWin.T channel runs from 293.15 to 298.15 K over 172,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 19,008 to 20,736 seconds. Subtracting 294.55 from 296.95 gives 2.4 K. Its location brackets the change within one saved interval of 1,728 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

conWin.T (K)

conWin.y (source units)

0

293.15

0

19008

294.55

0

20736

296.95

0

22464

298.15

0

34560

298.15

1

69120

293.15

0

103680

293.15

0

138240

298.15

0

172800

293.15

0

What to check on site

Record each condition, calculated request and issued output as separate tags. Keep timestamps and the sample or event rule with the export. A stable displayed value may be held by logic after the measured input has changed.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.