The published heaPum.P signal spans 0 to 2,940.535 W in the reference run. It starts at 0 and finishes at 2,940.535. The signed change between those endpoint samples is +2,940.535 W.

What the reference test measures

The Buildings model named ScrollWaterToWater_VariableSpeed comes from Lawrence Berkeley National Laboratory. The saved result covers simulation time 0 to 1,000 seconds. Industry Applied extracted 101 checkpoints for heaPum.P and kept the original signed values. The regular output spacing is 10 seconds. The solver may take different internal steps.

The model definition identifies heaPum (Scroll Water To Water), sin2 (Boundary p T), sin1 (Boundary p T). These component names let a reader trace the plotted tags to their owning blocks before reproducing the result.

Settings to preserve when repeating the experiment

The published test declares N.duration = 800, N.startTime = 100, N.height = 1.0. Those numbers use the units and component definitions in the linked model. Start with the declared configuration when reproducing the reference result, then vary one setting at a time. Changing the input waveform and the component response in the same comparison makes it difficult to identify the source of a difference.

Reading the two channels

The companion channel heaPum.QCon_flow spans 0 to 18,058.453 W across its 101 stored values. The primary trace first reaches its recorded maximum at 1,000 seconds and its minimum at 0 seconds. A time-aligned comparison preserves the meaning and units of each channel.

Electrical input to a variable-speed scroll heat pump. In the simulated ScrollWaterToWater_VariableSpeed case, heaPum.P ranges from 0 to 2,940.535 W over 1,000 seconds.
Electrical input to a variable-speed scroll heat pump. In the simulated ScrollWaterToWater_VariableSpeed case, heaPum.P ranges from 0 to 2,940.535 W over 1,000 seconds. Figure by Industry Applied.

Reproducing the largest recorded change

Between the stored points at 100 and 110 seconds, heaPum.P changes from 0 to 519.685. Subtracting the earlier reading gives +519.685 W. This interval contains the largest absolute point-to-point change in the saved primary channel. A faster excursion followed by recovery could fit entirely between the two records.

The extrema in the table and figure are extrema of the stored series. A solver’s internal peak, a field logger’s alarm value and a maximum derived from this export can differ. Preserve the sampling settings when comparing results.

Worked data

Simulation time (s)

heaPum.P (W)

heaPum.QCon_flow (W)

0

0

0

100

0

0

110

519.6847

794.0535

250

811.8955

4640.726

500

1485.712

10487.97

750

2329.947

15424.16

1000

2940.535

17953.55

Applying the result to an operating site

Compare electrical input with delivered condenser heat at the same time. Keep entering water temperatures and flow rates beside the speed command. A single input-power number cannot identify the COP or heating capacity at another operating condition.

For a local engineering comparison, write the measurement boundary, operating duty and instruments into the test record. Select comparable load or weather periods, then compare the measured trace with the simulated quantities. Establish a local acceptance tolerance using the intended duty and measurement uncertainty.