The signed flow trace gives a net 17.999 kg over 7,200 s, using the trapezoidal rule between saved samples. The smallest and largest reported rates are 0 kg/s and 0.005 kg/s. Check the positive flow direction in the model before using the sign to describe delivery or return.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named OneEffectiveAirLeakageArea. The source file places it under Airflow, Multizone. We used the 101 stored values for cra.m_flow over the interval 0 to 7,200 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name volA (Mixing Volume), volB (Mixing Volume), preHeaFlo (Prescribed Heat Flow), heaFloBou (Sine). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 3,096 s, cra.m_flow reads 0.0018001 kg/s and cra.v reads 0.75003 m/s. Across the run, the second channel ranges from 0 m/s to 2.0833 m/s. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Effective air leakage area. The simulated cra.m_flow channel runs from 0 to 0.005 kg/s over 7,200 seconds.
Effective air leakage area. The simulated cra.m_flow channel runs from 0 to 0.005 kg/s over 7,200 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 7,200 seconds gives a net 17.999 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

cra.m_flow (kg/s)

cra.v (m/s)

0

0

0

1440

0

0

2880

0.001499767

0.6249028

3024

0.001699461

0.7081088

3096

0.001800062

0.7500259

4320

0.003499623

1.458176

5472

0.005

2.083333

5760

0.005

2.083333

7200

0.005

2.083333

What to check on site

Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Units in the source model

The component declarations identify the scale of the exported variables. In this run, cra.v uses m/s. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.