The lowest observed group mean is 6.697 for nominal depth group 5.6. The highest is 7.657 for group 3.2, a difference of 0.96 on the source response scale. Across all 72 numeric records the response median is 6.99.

What was measured

The KAHN data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as mean peak impedance. It preserves the source scale and its sign. The file contains 7 numeric fields per accepted row.

Spread across the original readings

The two endpoint groups have 9 and 9 observations. Their medians are 6.72 and 7.7, respectively. The figure groups the original entries by the recorded nominal depth value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

Eddy-current inspection of steel axles. The lowest and highest group means are 6.697 and 7.657 on the source response scale.
Eddy-current inspection of steel axles. The lowest and highest group means are 6.697 and 7.657 on the source response scale. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 43 after the header. Its response is 7. The overall arithmetic mean is 7.071, so this observation is -0.07111 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 0.53, calculated by subtracting 6.805 from 7.335.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

nominal depth group

Observations

Mean response

Median response

Minimum response

Maximum response

3.2

9

7.656667

7.7

7.43

7.93

3.7

9

7.414444

7.48

7.09

7.62

4.1

9

7.247778

7.31

6.96

7.37

4.3

9

7.124444

7.17

6.83

7.26

4.6

9

6.926667

6.96

6.63

7.15

5

9

6.801111

6.86

6.54

6.92

5.2

9

6.701111

6.78

6.42

6.9

5.6

9

6.696667

6.72

6.42

6.85

Implications for an industrial comparison

A production acceptance sample should identify the item, instrument, operator and measurement method before the result is pooled. Document fixture setup and any intermediate processing. Repeatability from one instrument and reproducibility across operators or locations require different comparison groups.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.