The recorded dryWet.Q_flow channel spans -3,000 to -2,000 W in this reference run. It starts at -2,000 and ends at -3,000. The first recorded maximum occurs at 0 seconds and the first minimum at 31.2 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named DryWetSelector. The source file places it under Fluid, direct expansion Systems, Cooling. We used the 101 stored values for dryWet.Q_flow over the interval 0 to 60 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name XADP (Ramp), XEvaIn (Ramp), dryWet (Dry Wet Selector). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel dryWet.EIR starts at 0.2, ends at 0.3 and has a recorded range of 0.2 to 0.3 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Dry wet selector. The simulated dryWet.Q_flow channel runs from -3,000 to -2,000 W over 60 seconds.
Dry wet selector. The simulated dryWet.Q_flow channel runs from -3,000 to -2,000 W over 60 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed dryWet.Q_flow samples by the trapezoidal rule gives -0.04153 kWh over 60 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

dryWet.Q_flow (W)

dryWet.EIR (source units)

0

-2000

0.2

12

-2000

0.2

24

-2000

0.2

30

-2000

0.2

30.6

-2656.974

0.2656974

31.2

-3000

0.3

36

-3000

0.3

48

-3000

0.3

60

-3000

0.3

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.