The hex.sta_b1.T trace covers 24.393 to 49.262 °C, a temperature span of 24.869 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named DryCoilEffectivenessNTUPControl. The source file places it under Fluid, Heat Exchangers. We used the 101 stored values for hex.sta_b1.T over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name sin_2 (Boundary p T), sou_2 (Boundary p T), sin_1 (Boundary p T), sou_1 (Boundary p T). The source declares T_a1_nominal = 60 + 273.15, T_b1_nominal = 50 + 273.15, T_a2_nominal = 20 + 273.15, T_b2_nominal = 40 + 273.15. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel hex.sta_b2.T covers 295.15 to 312.224 K. At 0 s, the primary value is 322.412 and the companion is 312.224. Their signed difference is 10.188 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Dry coil effectiveness ntup control. The simulated hex.sta_b1.T channel runs from 297.543 to 322.412 K over 3,600 seconds.
Dry coil effectiveness ntup control. The simulated hex.sta_b1.T channel runs from 297.543 to 322.412 K over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 36 to 72 seconds. Subtracting 315.396 from 307.491 gives -7.905 K. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

hex.sta_b1.T (K)

hex.sta_b2.T (K)

0

322.412

312.2244

36

315.3963

305.8585

72

307.4909

299.0298

720

308.8586

300.15

1440

308.8585

300.15

2160

297.5765

295.1564

2736

297.543

295.15

2880

297.543

295.15

3600

297.543

295.15

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

Cover photograph by Jakub Zerdzicki, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.