The hex.sta_b1.T trace covers 20 to 35.018 °C, a temperature span of 15.018 K. The first recorded maximum occurs at 2,700 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named DryCoilDiscretizedPControl. The source file places it under Fluid, Heat Exchangers. We used the 101 stored values for hex.sta_b1.T over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name val (Two Way Equal Percentage), mot (Ideal Motor), con (Lim PID). The source declares m1_flow_nominal = 5. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel hex.sta_b2.T covers 293.15 to 305.142 K. At 108 s, the primary value is 297.652 and the companion is 302.831. Their signed difference is -5.179 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Dry coil discretized p control. The simulated hex.sta_b1.T channel runs from 293.15 to 308.168 K over 3,600 seconds.
Dry coil discretized p control. The simulated hex.sta_b1.T channel runs from 293.15 to 308.168 K over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 2,484 to 2,520 seconds. Subtracting 300.498 from 304.649 gives 4.151 K. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

hex.sta_b1.T (K)

hex.sta_b2.T (K)

0

293.15

293.15

720

303.1237

304.2884

1440

303.5652

300.7392

2160

298.3001

297.7768

2484

300.4977

301.7812

2520

304.6487

304.7981

2700

308.1675

304.1244

2880

307.4268

303.4129

3600

307.1592

303.515

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.