The lowest observed group mean is 344.5 for drill speed group 475. The highest is 487 for group 870, a difference of 142.5 on the source response scale. Across all 30 numeric records the response median is 327.5.

What was measured

The HAMAKER data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as thrust force. It preserves the source scale and its sign. The file contains 5 numeric fields per accepted row.

Spread across the original readings

The two endpoint groups have 6 and 6 observations. Their medians are 298 and 369, respectively. The figure groups the original entries by the recorded drill speed value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

Drill speed and thrust-force measurements. The lowest and highest group means are 344.5 and 487 on the source response scale.
Drill speed and thrust-force measurements. The lowest and highest group means are 344.5 and 487 on the source response scale. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 23 after the header. Its response is 324. The overall arithmetic mean is 393.1, so this observation is -69.1 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 446.25, calculated by subtracting 120.25 from 566.5.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

drill speed group

Observations

Mean response

Median response

Minimum response

Maximum response

100

6

390.3333

353.5

116

768

220

6

356

312.5

97

725

475

6

344.5

298

84

786

715

6

387.6667

336.5

58

892

870

6

487

369

70

1355

Implications for an industrial comparison

A production acceptance sample should identify the item, instrument, operator and measurement method before the result is pooled. Document fixture setup and any intermediate processing. Repeatability from one instrument and reproducibility across operators or locations require different comparison groups.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data