The mov.dpMachine trace ranges from -0.7599 Pa to 3,200 Pa across 101 saved checkpoints. It begins at 3,200 Pa and finishes at -0.7599 Pa after 1 s of test time. The source identifies the channel scale as Pa. Its first saved maximum occurs at 0 s.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named PressureCurve. The source file places it under Fluid, Movers. We used the 101 stored values for mov.dpMachine over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name mov (Speed Controlled y), one (Constant), bou1 (Mass Flow Source T), ram (Ramp). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The primary channel spends 70.3% of its saved checkpoints at or above 1,600 Pa, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 2,140 Pa. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Displays the pressure curve of the mover. The simulated mov.dpMachine channel runs from -0.7599 to 3,200 Pa over 1 seconds.
Displays the pressure curve of the mover. The simulated mov.dpMachine channel runs from -0.7599 to 3,200 Pa over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.71 to 0.72 seconds. Subtracting 1,552 from 1,493 gives -58.947 Pa. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

mov.dpMachine (Pa)

0

3199.975

0.2

2977.25

0.4

2840.638

0.6

2174.582

0.71

1552.402

0.72

1493.455

0.8

1032.008

1

-0.7598958

What to check on site

Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.