The etaApp trace ranges from 0.00099798 to 0.99883 across 101 saved checkpoints. It begins at 0.001 and finishes at 0.001 after 10 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named EulerCurve. The source file places it under Fluid, Movers. We used the 101 stored values for etaApp over the interval 0 to 10 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name x (Real), etaApp (Real), etaOri (Real). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
At 3.5 s, etaApp reads 0.79504 and etaOri reads 0.80465. Across the run, the second channel ranges from 0.0014519 to 1. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 3.4 to 3.5 seconds. Subtracting 0.7022 from 0.795 gives 0.09284 source units. Its location brackets the change within one saved interval of 0.1 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | etaApp (source units) | etaOri (source units) |
|---|---|---|
0 | 0.001 | 0.002479025 |
2 | 0.05787023 | 0.05951743 |
3.4 | 0.7021982 | 0.7288018 |
3.5 | 0.795037 | 0.8046507 |
4 | 0.9988331 | 1 |
6 | 0.2657623 | 0.2663651 |
8 | 0.02559857 | 0.02896131 |
9.9 | 0.0009979827 | 0.001717538 |
10 | 0.001 | 0.001451866 |
What to check on site
Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.