The largest absolute separation between HDirRoo.H and HDirWal.H is 535.31 W/m², at a saved time of 18,268,416 s. At that checkpoint the two values are 544.142 W/m² and 8.8317 W/m², respectively. This is a comparison between the named channels under the published test conditions.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named DirectTiltedSurface. The source file places it under Boundary Conditions, Solar Irradiation. We used the 101 stored values for HDirRoo.H over the interval 18,230,400 to 18,316,800 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name HDirRoo (Direct Tilted Surface), HDirFlo (Direct Tilted Surface), HDirWal (Direct Tilted Surface), assEqu (Assert Equality). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
At 18,268,416 s, HDirRoo.H is 544.142 W/m² and HDirWal.H is 8.8317 W/m². Subtracting the second value from the first gives 535.31 W/m². This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 18,277,056 to 18,277,920 seconds. Subtracting 386.957 from 297.144 gives -89.812 source units. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | HDirRoo.H (W/m²) | HDirWal.H (W/m²) |
|---|---|---|
1.82304e+07 | 0 | 0 |
1.824768e+07 | 0 | 0 |
1.826496e+07 | 464.3721 | 0 |
1.827187e+07 | 583.6971 | 131.1922 |
1.827706e+07 | 386.9568 | 192.667 |
1.827792e+07 | 297.1443 | 161.0365 |
1.828224e+07 | 142.1797 | 109.474 |
1.829952e+07 | 0 | 0 |
1.83168e+07 | 0 | 0 |
What to check on site
Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Units in the source model
The component declarations identify the scale of the exported variables. In this run, HDirRoo.H uses W/m² and HDirWal.H uses W/m². Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.