The recorded gen.PEle channel spans 400.682 to 62,935 W in this reference run. It starts at 6,025 and ends at 627.6. The first recorded maximum occurs at 107,136 seconds and the first minimum at 8,640 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named HeaterAndFixtureDirectHeatExchangerWithElectricHeat. The source file places it under DHC, Loads, Hot Water. We used the 101 stored values for gen.PEle over the interval 0 to 172,800 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name souCol (Boundary p T), theMixVal (Thermostatic Mixing Valve), souDisAmb (Mass Flow Source T), conTHotSet (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel theMixVal.conPID.y starts at 1, ends at 0.8333 and has a recorded range of 0.8333 to 1 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Reproduce the calculation
Integrating the signed gen.PEle samples by the trapezoidal rule gives 1,560 kWh over 172,800 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | gen.PEle (W) | theMixVal.conPID.y (source units) |
|---|---|---|
0 | 6024.96 | 1 |
8640 | 400.6817 | 0.8333333 |
19008 | 27462.55 | 0.8333333 |
20736 | 52313.43 | 0.8333333 |
34560 | 49823.5 | 0.8333333 |
69120 | 50701.71 | 0.8333333 |
103680 | 53911.93 | 0.8333333 |
107136 | 62935.4 | 0.8333333 |
138240 | 31251.22 | 0.8333333 |
172800 | 627.6 | 0.8333333 |
What to check on site
Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.