The recorded HDifFlo.H channel spans 0 to 110.623 source units in this reference run. It starts at 0 and ends at 0. The first recorded maximum occurs at 18,282,240 seconds and the first minimum at 18,230,400 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named DiffusePerez. The source file places it under Boundary Conditions, Solar Irradiation. We used the 101 stored values for HDifFlo.H over the interval 18,230,400 to 18,316,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name weaBus (Bus), HDifRoo (Diffuse Perez), HDifFlo (Diffuse Perez), HDifWal (Diffuse Perez). The source declares azi = 0.3, til = 0.5. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The two named channels have separate paths in the model. HDifFlo.H begins at 0 and ends at 0. HDifRoo.H begins at 0 and ends at 0. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Diffuse solar irradiation on a tilted surface using the perez. The simulated HDifFlo.H channel runs from 0 to 110.623 source units over 86,400 seconds.
Diffuse solar irradiation on a tilted surface using the perez. The simulated HDifFlo.H channel runs from 0 to 110.623 source units over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 18,280,512 to 18,281,376 seconds. Subtracting 91.516 from 103.67 gives 12.153 source units. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

HDifFlo.H (source units)

HDifRoo.H (source units)

1.82304e+07

0

0

1.824768e+07

0.488663

2.443315

1.826496e+07

59.59568

297.7848

1.828051e+07

91.51649

332.1687

1.828138e+07

103.6699

323.1477

1.828224e+07

110.6234

314.5024

1.829952e+07

1.188882

5.771386

1.83168e+07

0

0

What to check on site

Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model