The largest absolute separation between HDifFlo.H and HDifRoo.H is 327.765 W/m², at a saved time of 18,273,600 s. At that checkpoint the two values are 80.353 W/m² and 408.118 W/m², respectively. This is a comparison between the named channels under the published test conditions.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named DiffuseIsotropic. The source file places it under Boundary Conditions, Solar Irradiation. We used the 101 stored values for HDifFlo.H over the interval 18,230,400 to 18,316,800 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name weaBus (Bus), HDifRoo (Diffuse Isotropic), HDifFlo (Diffuse Isotropic), HDifWal (Diffuse Isotropic). The source declares rho = 0.2. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
At 18,273,600 s, HDifFlo.H is 80.353 W/m² and HDifRoo.H is 408.118 W/m². Subtracting the second value from the first gives -327.765 W/m². This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 18,280,512 to 18,281,376 seconds. Subtracting 91.516 from 103.67 gives 12.153 source units. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | HDifFlo.H (W/m²) | HDifRoo.H (W/m²) |
|---|---|---|
1.82304e+07 | 2e-05 | 0.0001 |
1.824768e+07 | 0.488663 | 2.443315 |
1.826496e+07 | 59.59568 | 297.7848 |
1.828051e+07 | 91.51649 | 332.1687 |
1.828138e+07 | 103.6699 | 323.1477 |
1.828224e+07 | 110.6234 | 314.5024 |
1.829952e+07 | 1.188882 | 5.771386 |
1.83168e+07 | 2e-05 | 0.0001 |
What to check on site
Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Units in the source model
The component declarations identify the scale of the exported variables. In this run, HDifFlo.H uses W/m² and HDifRoo.H uses W/m². Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.