The flxBou.T trace covers 15 to 30 °C, a temperature span of 15 K. The first recorded maximum occurs at 15.6 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named TemperatureKpis. The source file places it under Utilities, KP Is. We used the 101 stored values for flxBou.T over the interval 0 to 120 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name traT (Trapezoid), from_degC (From deg C), booPulAct (Boolean Pulse), fixBou (Fixed Bounds). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel traT.y starts at 15, ends at 15 and has a recorded range of 15 to 30 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 39.6 to 40.8 seconds. Subtracting 293.55 from 292.35 gives -1.2 K. Its location brackets the change within one saved interval of 1.2 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | flxBou.T (K) | traT.y (source units) |
|---|---|---|
0 | 288.15 | 15 |
15.6 | 303.15 | 30 |
24 | 303.15 | 30 |
39.6 | 293.55 | 20.4 |
40.8 | 292.35 | 19.2 |
48 | 288.15 | 15 |
72 | 300.15 | 27 |
96 | 297.15 | 24 |
120 | 288.15 | 15 |
What to check on site
Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.