The traCo2Con.y trace ranges from 400 to 2,000 across 101 saved checkpoints. It begins at 400 and finishes at 400 after 120 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

The largest change in traCo2Con.y between saved samples lies between simulation times 9.6 s and 10.8 s. The channel moves from 1,424 to 1,552 across that interval. A finer export is needed to resolve what happens between those observations.

The component declarations name traCo2Con (Trapezoid), booPulAct (Boolean Pulse), fixBou (Co2 Fixed Limit), fixBouAct (Co2 Fixed Limit). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 10.8 s, traCo2Con.y reads 1,552 and booPulAct.y reads 1. Across the run, the second channel ranges from 0 to 1. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 9.6 to 10.8 seconds. Subtracting 1,424 from 1,552 gives 128 source units. Its location brackets the change within one saved interval of 1.2 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

traCo2Con.y (source units)

booPulAct.y (source units)

0

400

1

9.6

1424

1

10.8

1552

1

15.6

2000

1

24

2000

1

48

400

0

72

1680

1

96

1360

0

120

400

0

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.