The y trace ranges from 644.748 to 404,919.7 across 101 saved checkpoints. It begins at 644.748 and finishes at 404,919.7 after 2 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named DewPointTemperatureDerivativeCheck_amb. The source file places it under Utilities, Psychrometrics, Functions. We used the 101 stored values for y over the interval -1 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name y (Real), y_comp (Real), err (Real), T (Temperature). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The two named channels have separate paths in the model. y begins at 644.75 and ends at 4.0492e+05. y_comp begins at 644.75 and ends at 4.0492e+05. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.98 to 1 seconds. Subtracting 335,040 from 404,920 gives 69,879 source units. Its location brackets the change within one saved interval of 0.02 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

y (source units)

y_comp (source units)

-1

644.7478

644.7478

-0.6

8057.451

8057.451

-0.2

15746.62

15746.62

0.2

16579.49

16579.49

0.6

32401.2

32401.2

0.98

335040.3

335040.3

1

404919.7

404919.7

What to check on site

Record the physical quantity and its reference state before checking agreement. A sensor model can include a delay or mixing volume that an algebraic reference omits. Align both acquisition time and location before interpreting a difference as calibration error.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Checking the two recorded channels

At 1 s, y reads 404,919.7 and y_comp reads 404,919.7. Across the run, the second channel ranges from 644.748 to 404,919.7. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.