The dewBulPhi.TDewPoi trace covers -66.573 to 29.406 °C, a temperature span of 95.978 K. The first recorded maximum occurs at 1 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named DewPoint_TDryBulPhi. The source file places it under Controls, OBC, CDL, Psychrometrics. We used the 101 stored values for dewBulPhi.TDewPoi over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name dewBulPhi (Dew Point T Dry Bul Phi), dewBulPhi1 (Dew Point T Dry Bul Phi), phi (Ramp), TDryBul (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel dewBulPhi1.TDewPoi covers 262.668 to 294.32 K. At 0 s, the primary value is 206.577 and the companion is 262.668. Their signed difference is -56.091 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Dew point t dry bul phi. The simulated dewBulPhi.TDewPoi channel runs from 206.577 to 302.556 K over 1 seconds.
Dew point t dry bul phi. The simulated dewBulPhi.TDewPoi channel runs from 206.577 to 302.556 K over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 0.01 seconds. Subtracting 206.577 from 239.203 gives 32.626 K. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

dewBulPhi.TDewPoi (K)

dewBulPhi1.TDewPoi (K)

0

206.5773

262.6685

0.01

239.2032

262.9985

0.2

277.3549

269.188

0.4

287.62

275.575

0.6

294.0165

281.8735

0.8

298.7554

288.1147

1

302.5556

294.3199

What to check on site

Record the physical quantity and its reference state before checking agreement. A sensor model can include a delay or mixing volume that an algebraic reference omits. Align both acquisition time and location before interpreting a difference as calibration error.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.