The zone__toilet.TSensor trace ranges from 290.207 to 295.15 across 101 saved checkpoints. It begins at 295.15 and finishes at 290.207 after 604,800 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

The largest change in zone__toilet.TSensor between saved samples lies between simulation times 368,928 s and 374,976 s. The channel moves from 292.284 to 292.21 across that interval. A finer export is needed to resolve what happens between those observations.

The component declarations name window_living_controlsignal (Real Input), window_hall_controlsignal (Real Input), window_diner_controlsignal (Real Input), window_bed_strt1_controlsignal (Real Input). The source declares m_flow_nominal = 1, etaHydPar = 0.5. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The two named channels have separate paths in the model. zone__toilet.TSensor begins at 295.15 and ends at 290.21. zone__kitchen.TSensor begins at 294.99 and ends at 288.64. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 368,928 to 374,976 seconds. Subtracting 292.284 from 292.21 gives -0.07364 source units. Its location brackets the change within one saved interval of 6,048 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

zone__toilet.TSensor (source units)

zone__kitchen.TSensor (source units)

0

295.15

294.9896

120960

293.9918

292.7613

241920

293.3477

293.158

362880

292.344

291.1461

368928

292.2836

291.0305

374976

292.21

291.0299

483840

291.2246

290.9278

604800

290.207

288.636

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Checking the two recorded channels

At 374,976 s, zone__toilet.TSensor reads 292.21 and zone__kitchen.TSensor reads 291.03. Across the run, the second channel ranges from 288.636 to 295.477. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.