The recorded winEas.y channel spans 0 to 610.295 source units in this reference run. It starts at 0 and ends at 0. The first recorded maximum occurs at 26,784 seconds and the first minimum at 0 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named BeamDepthInRoom. The source file places it under Heat Transfer, Windows. We used the 101 stored values for winEas.y over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name winEas (Beam Depth In Room), winSou (Beam Depth In Room), winWes (Beam Depth In Room), winNor (Beam Depth In Room). The source declares hApe = 2.0, depOve = 1.0, gapOve = 0.5. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel winSou.y covers 0 to 380.116 source units. At 26,784 s, the primary value is 610.295 and the companion is 380.116. Their signed difference is 230.178 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 25,920 to 26,784 seconds. Subtracting 0 from 610.295 gives 610.295 source units. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | winEas.y (source units) | winSou.y (source units) |
|---|---|---|
0 | 0 | 0 |
17280 | 0 | 0 |
25920 | 0 | 0 |
26784 | 610.2946 | 380.1162 |
34560 | 1.925654 | 3.50475 |
51840 | 0 | 3.671155 |
69120 | 0 | 0 |
86400 | 0 | 0 |
What to check on site
Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.