The recorded PCon.y channel spans 3 to 4.999 source units in this reference run. It starts at 3 and ends at 4.999. The first recorded maximum occurs at 5,270,400 seconds and the first minimum at 0 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named LinearInputDayOfAdjustment. The source file places it under Controls, Predictors. We used the 101 stored values for PCon.y over the interval 0 to 5,270,400 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 16 recorded variables. Alongside the primary output there are PCon.y, baseLoad.PPre[1], baseLoad.storeHistory, baseLoad.typeOfDay[1], baseLoad.adj. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The companion channel baseLoad.PPre[1] starts at 0, ends at 4.999 and has a recorded range of 0 to 4.999 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 2,687,904 to 2,740,608 seconds. Subtracting 4.019 from 4.04 gives 0.02049 source units. Its location brackets the change within one saved interval of 52,704 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | PCon.y (source units) | baseLoad.PPre[1] (source units) |
|---|---|---|
0 | 3 | 0 |
1054080 | 3.398907 | 3.398907 |
2108160 | 3.79918 | 3.79918 |
2687904 | 4.019125 | 4.019125 |
2740608 | 4.039618 | 4.039618 |
3162240 | 4.199453 | 4.188514 |
4216320 | 4.599727 | 4.599727 |
5270400 | 4.998634 | 4.998634 |
What to check on site
Record each condition, calculated request and issued output as separate tags. Keep timestamps and the sample or event rule with the export. A stable displayed value may be held by logic after the measured input has changed.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.