The recorded pum.m_flow channel spans 0 to 2.686 kg/s in this reference run. It starts at 0 and ends at 0. The first recorded maximum occurs at 24,192 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named DecouplingMixing. The source file places it under Fluid, Hydronic Configurations, Active Networks. We used the 101 stored values for pum.m_flow over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name con1 (Single Mixing), resT2 (PID With Operating Mode), T2SetVar (Line), yValSet (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel con.res3.m_flow covers 0 to 0.2153 kg/s. At 24,192 s, the primary value is 2.686 and the companion is 0.199. Their signed difference is 2.487 kg/s, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Decoupling circuit serving a single mixing circuit. The simulated pum.m_flow channel runs from 0 to 2.686 kg/s over 86,400 seconds.
Decoupling circuit serving a single mixing circuit. The simulated pum.m_flow channel runs from 0 to 2.686 kg/s over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 86,400 seconds gives a net 78,373 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

pum.m_flow (kg/s)

con.res3.m_flow (kg/s)

0

0

0

17280

0

0

21600

0

0

22464

2.537407

0.1996997

24192

2.686116

0.1990038

34560

1.474608

0.2048521

51840

0.5944282

0.2131201

69120

1.69487

0.2036542

86400

0

0

What to check on site

Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.