The lowest observed group mean is 23.456 for day group 1 to 5. The highest is 24.4 for group 16 to 20, a difference of 0.944 on the source response scale. Across all 100 numeric records the response median is 23.65.

What was measured

The CCXBAR data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as specimen thickness. It preserves the source scale and its sign. The file contains 2 numeric fields per accepted row.

Spread across the original readings

The two endpoint groups have 25 and 25 observations. Their medians are 23.5 and 24.3, respectively. The figure groups the original entries by the recorded day value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

Day-to-day silicon wafer thickness. The lowest and highest group means are 23.456 and 24.4 on the source response scale.
Day-to-day silicon wafer thickness. The lowest and highest group means are 23.456 and 24.4 on the source response scale. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 3 after the header. Its response is 23.7. The overall arithmetic mean is 23.726, so this observation is -0.026 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 1.05, calculated by subtracting 23.1 from 24.15.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

day group

Observations

Mean response

Median response

Minimum response

Maximum response

1 to 5

25

23.456

23.5

22.4

25

6 to 10

25

23.46

23.4

22.5

24.9

11 to 15

25

23.588

23.7

22.2

24.9

16 to 20

25

24.4

24.3

22.1

27.8

Implications for an industrial comparison

Record fixture connections, instrument range, excitation level and temperature alongside the measured result. Repeatability within one setup can remain good even when fixtures differ between laboratories. A useful acceptance run includes both a repeat measurement without disturbing the setup and a repeat after a normal reconnection.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.