The lowest observed group mean is -5.678 for day group 38 to 50. The highest is -3.981 for group 1 to 13, a difference of 1.698 on the source response scale. Across all 50 numeric records the response median is -5.015.

What was measured

The PURYEAR data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as deviation of an industrial process from target. It preserves the source scale and its sign. The file contains 3 numeric fields per accepted row.

Spread across the original readings

The two endpoint groups have 13 and 13 observations. Their medians are -5.88 and -3.79, respectively. The figure groups the original entries by the recorded day value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

Day-to-day industrial process deviation. The lowest and highest group means are -5.678 and -3.981 on the source response scale.
Day-to-day industrial process deviation. The lowest and highest group means are -5.678 and -3.981 on the source response scale. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 18 after the header. Its response is -5.15. The overall arithmetic mean is -4.895, so this observation is -0.2548 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 1.52, calculated by subtracting -5.725 from -4.205.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

day group

Observations

Mean response

Median response

Minimum response

Maximum response

1 to 13

13

-3.980769

-3.79

-5.89

-2.27

14 to 25

12

-5.579167

-5.51

-7

-4.34

26 to 37

12

-4.353333

-4.31

-5.73

-3.46

38 to 50

13

-5.678462

-5.88

-6.82

-4.32

Implications for an industrial comparison

A production acceptance sample should identify the item, instrument, operator and measurement method before the result is pooled. Document fixture setup and any intermediate processing. Repeatability from one instrument and reproducibility across operators or locations require different comparison groups.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.