The chiSwi.TSet trace covers -269.15 to -253.152 °C, a temperature span of 15.998 K. The first recorded maximum occurs at 11,232 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ChillerSwitch. The source file places it under Chiller Plant, Data Center, Controls. We used the 101 stored values for chiSwi.TSet over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 3 recorded variables. Alongside the primary output there are chiSwi.chiCHWST, chiSwi.TSet, chiSwi.y. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel chiSwi.y starts at 0, ends at 0 and has a recorded range of 0 to 1 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Data centre chiller switch. The simulated chiSwi.TSet channel runs from 4 to 19.998 K over 86,400 seconds.
Data centre chiller switch. The simulated chiSwi.TSet channel runs from 4 to 19.998 K over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 34,560 to 35,424 seconds. Subtracting 7.799 from 16.064 gives 8.265 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

chiSwi.TSet (K)

chiSwi.y (source units)

0

12

0

11232

19.99795

0

17280

14.18362

0

34560

7.798603

1

35424

16.06367

0

51840

17.9001

0

58752

4.000025

1

69120

4.849268

1

86400

19.8583

0

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.