The soi.port_a.T trace covers 22 to 30.817 °C, a temperature span of 8.817 K. The first recorded maximum occurs at 360,000 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Cylindrical. The source file places it under Fluid, Geothermal, Borefields, Heat Transfer. We used the 101 stored values for soi.port_a.T over the interval 0 to 360,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name soi (Cylindrical), preTem (Fixed Temperature), heaFlo (Step), preHeaFlo (Prescribed Heat Flow). The source declares T_start = 295.15. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The primary channel spends 94.1% of its saved checkpoints at or above 299.559 K, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 302.454 K. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Cylindrical with the ground temperature response. The simulated soi.port_a.T channel runs from 295.15 to 303.967 K over 360,000 seconds.
Cylindrical with the ground temperature response. The simulated soi.port_a.T channel runs from 295.15 to 303.967 K over 360,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 3,600 seconds. Subtracting 295.15 from 297.486 gives 2.336 K. Its location brackets the change within one saved interval of 3,600 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

soi.port_a.T (K)

0

295.15

3600

297.4864

72000

301.5047

144000

302.5479

216000

303.1699

288000

303.6184

360000

303.9673

What to check on site

The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.