The recorded G[1] channel spans 0 to 0.5704 source units in this reference run. It starts at 0 and ends at 0.5704. The first recorded maximum occurs at 15 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named CylindricalHeatSource. The source file places it under Fluid, Geothermal, Borefields, Heat Transfer, Thermal Response Factors. We used the 101 stored values for G[1] over the interval 0 to 15 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name t (Time). The source declares aSoi = 1.0e-6, rSource = 0.075. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel G[2] covers -3.76e-06 to 0.4612 source units. At 15 s, the primary value is 0.5704 and the companion is 0.4612. Their signed difference is 0.1093 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Cylindrical heat source. The simulated G[1] channel runs from 0 to 0.5704 source units over 15 seconds.
Cylindrical heat source. The simulated G[1] channel runs from 0 to 0.5704 source units over 15 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 14.85 to 15 seconds. Subtracting 0.5586 from 0.5704 gives 0.01186 source units. Its location brackets the change within one saved interval of 0.15 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

G[1] (source units)

G[2] (source units)

0

0

0

3

0.009186349

-3.72534e-06

6

0.04206171

0.000100527

9

0.1444156

0.04874136

12

0.3379822

0.2297074

14.85

0.5585831

0.4493393

15

0.5704417

0.4611892

What to check on site

The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.