The Nu trace ranges from 3.66 to 71.972 across 101 saved checkpoints. It begins at 3.66 and finishes at 71.972 after 10,000 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ConvectionResistanceCircularPipe. The source file places it under Fluid, Geothermal, Borefields, Boreholes, Functions. We used the 101 stored values for Nu over the interval 0 to 10,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name Re (Real), Nu (Real), m_flow (Mass Flow Rate), RConv (Thermal Resistance). The source declares hSeg = 1.0, rTub = 0.02, eTub = 0.002, kMed = 0.6. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 2,400 s, Nu reads 22.979 and RConv reads 0.023087. Across the run, the second channel ranges from 0.0073712 to 0.14495. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 2,300 to 2,400 seconds. Subtracting 3.66 from 22.979 gives 19.319 source units. Its location brackets the change within one saved interval of 100 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

Nu (source units)

RConv (source units)

0

3.66

0.1449499

2000

3.66

0.1449499

2300

3.66

0.1449499

2400

22.97905

0.02308697

4000

34.57889

0.01534221

6000

47.8282

0.01109213

8000

60.20534

0.008811785

10000

71.97191

0.007371161

What to check on site

The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.