The signed flow trace gives a net 87,243 kg over 432,000 s, using the trapezoidal rule between saved samples. The smallest and largest reported rates are -2.476e-13 kg/s and 0.5 kg/s. Check the positive flow direction in the model before using the sign to describe delivery or return.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named FixedApproachWetBulb. The source file places it under Fluid, Heat Exchangers, Cooling Towers. We used the 101 stored values for tow.m_flow over the interval 15,552,000 to 15,984,000 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 5 recorded variables. Alongside the primary output there are tow.TAir, tow.vol.heatPort.Q_flow, tow.m_flow, onOffCon.u, onOffCon.reference. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

At 15,642,720 s, tow.m_flow reads -2.476e-13 kg/s and tow.vol.heatPort.Q_flow reads 7.763e-09 W. Across the run, the second channel ranges from -23,083.7 W to 7.763e-09 W. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Cooling tower with fixed approach temperature using the wet-bulb temperature. The simulated tow.m_flow channel runs from 0 to 0.5 kg/s over 432,000 seconds.
Cooling tower with fixed approach temperature using the wet-bulb temperature. The simulated tow.m_flow channel runs from 0 to 0.5 kg/s over 432,000 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 432,000 seconds gives a net 87,243 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

tow.m_flow (kg/s)

tow.vol.heatPort.Q_flow (W)

1.5552e+07

0

0

1.556928e+07

0.5

-17021.38

1.56384e+07

0.5

-15806.49

1.564272e+07

0

7.762522e-09

1.57248e+07

0.5

-20089.07

1.58112e+07

0

-2.761696e-08

1.58976e+07

0.1244381

-4224.09

1.5984e+07

0

0

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.